erations performed by the PQF mill. The cir-
cumferential wall-thickness profile reveals
the effects of the pressure balance among
the three PQF rolls, helping operators
identify adjustments that may be required
to improve wall uniformity. The cycle-anal-
ysis functions included in the Lut data-pro-
cessing software analyze the longitudinal
wall-thickness profile and help distinguish
between different sources of periodic
eccentricity. For example, the analysis can
indicate whether a recurring wall-thickness
variation is more likely associated with
non-uniform heating or with the piercing
plug. The results of the measurements are
presented through clear, easy-to-read op-
erator displays, enabling plant personnel to
Data display for Lut DPS
recognize abnormal dimensional patterns
more quickly, identify their probable origin
and take corrective action before a larger
quantity of production is affected.
The second Lut DPS is positioned at the
output of the SRM. Using Tecnar’s dig-
ital-twin processing, the system recon-
structs the complete wall-thickness distri-
bution and generates average, minimum
and maximum wall-thickness profiles along
the product length. Because of the smaller
finished diameter, competing technologies
are typically limited to average wall-thick-
ness measurements at this location. In
contrast, the Lut DPS continues to provide
the same detailed dimensional informa-
tion available on larger-diameter products,
including both the longitudinal wall-thick-
ness profile and the radial profile around
the circumference. Operators can therefore
identify not only variations along the tube
or pipe length but also localized thin and
thick regions around the wall, providing a
substantially more complete representa-
tion of the finished product.
Data from the two Lut systems are used
average wall thickness over the maximum
usable product length.
In addition to the average profile supplied
for process control, the minimum wall-thick-
ness profile provides a further advantage
available from the Lut DPS at the SRM
output. It gives operators and process spe-
cialists a direct indication of the lowest local
wall thickness along the product, allowing
the performance of the control strategy to
be assessed while supporting operation
closer to the lower wall-thickness tolerance
without compromising product compliance.
The result is improved material utilization
together with more consistent wall-thickness
performance from end to end.
The Lut gauge at the SRM also clearly iden-
tifies the tapered regions at the front and
rear ends of the product. This information
can be used to optimize cutting positions
automatically, reducing the amount of
material removed while ensuring that the
finished product remains within dimension-
al tolerances.
by the SMS CARTA®neo process-control
system for automated feedback control of
Where automated feedback control is not
the SRM. In particular, the average longitu-
implemented, the same measurement data
dinal wall-thickness profile reconstructed
remain valuable for mill setup, process
by the Lut DPS provides CARTA®neo with
troubleshooting and the refinement of
real-time information on how the wall thick-
production models. Operators and process
ness changes along the tube or pipe. By
specialists can compare the profiles meas-
comparing the dimensional results meas-
ured before and after the SRM to deter-
ured before and after stretch reduction, the
mine where dimensional variations origi-
control system can determine the appro-
nate and where corrective action should be
priate process corrections and stabilize the
applied.ITAtube Journal September 2026 45